Perkins 1106 — Fuel Priming Pump - Remove and Install (Mechanical Priming Pump)
Maintenance
For the Perkins 1106, from the Perkins service manual.
Applies to: Perkins 1106, Perkins 1106D engine
Before you start
- Fuel system work by authorised personnel only
Procedure
- Isolate the fuel supply.
- Mark plastic tube assemblies for correct position.
- Place container below pump; drain the primary filter.
- Disconnect plastic tube assemblies and plug/cap ports.
- Remove primary filter from fuel priming pump.
- Remove bolts and remove fuel priming pump from mounting bracket.
- If required, remove connectors, plugs and O-ring seals to disassemble pump.
- On installation, install new O-ring seals to connectors and plugs.
- Tighten plugs and connectors to 20 N·m.
- Position pump on bracket, install bolts, tighten to 44 N·m.
- Install new primary filter; connect tube assemblies in original positions.
- Restore fuel supply and prime the fuel system.
Specs & values
- 20 N·m (14 lb ft) plugs and connectors
- 44 N·m (32 lb ft) mounting bolts
Full service-parts list: Perkins 1106 →, Perkins 1106D engine →