Perkins 1106 — Engine Air Cleaner Element (Dual Element) - Clean/Replace

Maintenance

For the Perkins 1106, from the Perkins owner's manual.

Applies to: Perkins 1106

Before you start

  • Never run the engine without an air cleaner element installed.

Parts for this job

Part numbers from the service-parts list for Perkins 1106. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Remove the cover and remove the primary air cleaner element.
  2. The secondary air cleaner element should be removed and discarded for every three cleanings of the primary element.
  3. Cover the air inlet with tape in order to keep dirt out.
  4. Clean the inside of the air cleaner cover and body with a clean, dry cloth.
  5. Remove the tape from the air inlet. Install the secondary element and a new or cleaned primary element.
  6. Install the air cleaner cover.
  7. Reset the air cleaner service indicator.

Specs & values

  • Pressurized air cleaning: use filtered dry air with a maximum pressure of 207 kPa (30 psi)

Full service-parts list: Perkins 1106 →

Source: Perkins owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.