Home›Repair guides›Perkins›Water Pump - Install

Perkins 1104D — Water Pump - Install

Maintenance

For the Perkins 1104D, from the Perkins service manual.

Browse Perkins generators & specs →

Procedure

  1. Ensure water pump clean and free from wear or damage; replace if necessary.
  2. If necessary, install cover to water pump: clean cover surface, position new joint, install cover, install bolts finger tight.
  3. Clean mating surface of front cover.
  4. Install guide studs in position.
  5. Use guide studs to align new joint to front cover; install joint.
  6. Align water pump with guide studs; install to front cover.
  7. Install bolts finger tight.
  8. Remove guide studs and install remaining bolts finger tight.
  9. Tighten bolts to 22 N·m (16 lb ft) in sequence.
  10. Install hose to water pump inlet; tighten hose clamps.
  11. Fill cooling system with coolant.

Tools required

  • Guide Stud (M8 by 80 mm) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 22 N·m (16 lb ft)

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.