Home›Repair guides›Perkins›Electronic Control Module - Remove and Install

Perkins 1104 — Electronic Control Module - Remove and Install

Maintenance

For the Perkins 1104, from the Perkins service manual.

Applies to: Perkins 1104, Perkins N H1 (Engine) engine

Procedure

  1. Isolate electrical supply to engine.
  2. If ECM equipped with fuel supply, isolate fuel supply.
  3. Cut cable tie; disconnect machine wiring harness from ECM.
  4. Cut cable ties; disconnect engine harness from ECM.
  5. If equipped, disconnect plastic tube assemblies.
  6. Remove bolts and remove ECM assembly; note bracket positions and orientation.
  7. Remove bolts and washers from ECM; note ground strap position.
  8. If necessary, disassemble ECM: remove isolation mounts, spacers, connectors, O-ring seals, brackets.
  9. If replacement ECM installed, program with correct information.
  10. Ensure ECM clean and free from damage.
  11. If necessary, assemble ECM: install new O-ring seals to connectors, install brackets, install isolation mounts and spacers.
  12. Install washers and bolts to ECM.
  13. Install ECM assembly to mounting bracket; tighten bolts to 22 N·m (16 lb ft).
  14. Connect engine wiring harness; tighten bolt to 5 N·m (44 lb in).
  15. Connect machine wiring harness; tighten bolt to 5 N·m (44 lb in).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 18.5 N·m (13.6 lb ft)
  • 14 N·m (10 lb ft)
  • 20 N·m (14 lb ft)
  • 22 N·m (16 lb ft)
  • 5 N·m (44 lb in)

Full service-parts list: Perkins 1104 →

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →