Perkins 1103 / 1104 — Water Temperature Regulator - Test

Testing & diagnosis · Cooling System

For the Perkins 1103 / 1104, from the Perkins service manual.

Applies to: Perkins 1103, Perkins 1104, Perkins 1104 (1103 also covered) engine

Procedure

  1. Remove the water temperature regulator housing from the engine.
  2. Heat water in a pan to the fully open temperature of the regulator and stir to distribute temperature.
  3. Hang the housing in the pan below the water surface, away from pan sides and bottom.
  4. Keep the water at the correct temperature for ten minutes.
  5. Remove the housing and immediately measure the opening of the regulator; replace if less than listed.

Specs & values

  • Keep water at the correct temperature for ten minutes.

Full service-parts list: Perkins 1103 →, Perkins 1104 →

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.