Home›Repair guides›Perkins›Water Pump - Assemble

Perkins 1103 / 1104 — Water Pump - Assemble

Repair & overhaul

For the Perkins 1103 / 1104, from the Perkins service manual.

Applies to: Perkins 1103, Perkins 1104

Procedure

  1. Clean inside of housing; ensure bores clean and free from corrosion.
  2. Press new oil seal into housing until level with recess.
  3. Install gear; press shaft through oil seal into gear.
  4. Press bearing against shoulder; install new circlips.
  5. Press needle bearing into housing.
  6. Press new coolant seal onto shaft into counterbore.
  7. Press impeller onto shaft until level with shaft top.
  8. Install cover with new joint; tighten setscrews to 22 N·m.

Specs & values

  • 22 N·m

Full service-parts list: Perkins 1103 →, Perkins 1104 →

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Perkins repair guides →