Home›Repair guides›Perkins›Valve Guide - Inspect

Perkins 1103 / 1104 — Valve Guide - Inspect

Maintenance · Cylinder Head Valves

For the Perkins 1103 / 1104, from the Perkins service manual.

Applies to: Perkins 1103, Perkins 1104, Perkins 1104 (1103 also covered) engine

Procedure

  1. Place a new valve in the valve guide.
  2. Place a suitable dial indicator with magnetic base on the face of the cylinder head.
  3. Lift the edge of the valve head to a distance of 15.0 mm (0.60 inch).
  4. Move the valve radially away from the dial indicator as far as possible and set the needle to zero.
  5. Move the valve radially toward the dial indicator as far as possible and note the movement.
  6. If the distance is greater than the maximum clearance, replace the valve guide; new valves and valve seat inserts must be installed.

Tools required

  • Dial indicator with magnetic base Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Lift the edge of the valve head 15.0 mm (0.60 inch).

Full service-parts list: Perkins 1103 →, Perkins 1104 →

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.