Operation

For the Perkins 1103 / 1104, from the Perkins service manual.

Applies to: Perkins 1103, Perkins 1104, Perkins 1104 (1103 also covered) engine

Procedure

  1. Delphi DP210 and Delphi STP: position the starting switch to RUN for three minutes; air is purged automatically.
  2. Bosch EPVE: remove the valve mechanism cover.
  3. Turn the start switch to RUN for three minutes, then return to OFF.
  4. Loosen the high pressure lines at the fuel injectors.
  5. Operate the starting motor until fuel free from air comes from the connections.
  6. Tighten the fuel injector connections, operate the engine and check for leaks, then fit the valve mechanism cover.

Full service-parts list: Perkins 1103 →, Perkins 1104 →

Source: Perkins service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.