Procedure

  1. Drain and flush the radiator and cooling system. Refill with antifreeze-water mixture. Run engine to circulate antifreeze.
  2. Fill the fuel tank or add biocide as per manufacturer's instructions.
  3. Change the crankcase oil and filter.
  4. Seal the air cleaner inlet, exhaust opening, crankcase breather pipe and fuel tank vent with plastic bags and tape.
  5. Loosen the alternator belt.
  6. Disconnect and clean battery; remove to warm storage place if possible.
  7. Clean outside of unit, paint scratched or chipped surfaces, apply corrosion preventative to exposed metal.
  8. Store the set in a dry, protected place.