Northern Lights NL498D2 / NL498K2 — Winterizing / Out-of-Service
Maintenance · Generator set
For the Northern Lights NL498D2 / NL498K2, from the Northern Lights operator's manual.
Applies to: Northern Lights NL498D2
Procedure
- Drain and flush radiator and cooling system; leave dry or refill with antifreeze-water mixture.
- Fill fuel tank or add biocide per manufacturer's instructions.
- Seal air cleaner inlet, exhaust opening, crankcase breather pipe, and fuel tank vent with plastic bags and tape.
- Change crankcase oil and filter.
- Loosen alternator belt.
- Disconnect and clean battery; remove to warm storage if possible.
- Clean outside of unit; paint scratched surfaces and apply corrosion preventative to exposed metal.
- Store set in dry, protected place; cover if stored outside.
Full service-parts list: Northern Lights NL498D2 →
Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.