Home›Repair guides›Northern Lights›Install wet exhaust outlet tube

Northern Lights M844LW3 / M844W3 — Install wet exhaust outlet tube

Installation · Wet exhaust outlet tube kit (item 23)

For the Northern Lights M844LW3 / M844W3, from the Northern Lights service manual.

Applies to: Northern Lights M844LW3, Northern Lights M844W3

Procedure

  1. Note the tube (item 23) shape: short curved end connects to exhaust elbow, longer end goes through rear panel.
  2. Apply rubber lubricant to the inside of the short blue silicone hose and push it onto the tube.
  3. Apply rubber lubricant to the grommet and squeeze the barbed end through the grommet hole.
  4. Install the four hose clamps without tightening; rotate the tube to its best position.
  5. Push the blue hose onto the genset exhaust elbow, position clamps and tighten.

Full service-parts list: Northern Lights M844LW3 →, Northern Lights M844W3 →

Source: Northern Lights service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Northern Lights repair guides →