Northern Lights M844LW3 / M844W3 — Install siphon break (optional)
Installation · Penetration panel assembly (item 13) / siphon break
For the Northern Lights M844LW3 / M844W3, from the Northern Lights service manual.
Applies to: Northern Lights M844LW3, Northern Lights M844W3
Before you start
- Generator sets with wet exhaust installed near or below the vessel's water line must use a siphon break to prevent backflow of water into the engine.
Procedure
- Position the siphon break a minimum of 12 inches above the vessel's loaded water line.
- Remove white plastic hole plugs from the penetration plate and replace with two rubber grommets (item 21).
- Install sound foam (item 22) to the underside of the penetration plate.
- Pass seawater pump output hose through the front hole and expansion tank hose through the side hole.
Specs & values
- Siphon break mounted a minimum of 12 inches above the vessel's loaded water line
Full service-parts list: Northern Lights M844LW3 →, Northern Lights M844W3 →