Home›Repair guides›Northern Lights›Valve Clearance Adjustment

Northern Lights M773L — Valve Clearance Adjustment

Adjustments · valve train

For the Northern Lights M773L, from the Northern Lights operator's manual.

Applies to: Northern Lights M773L

Procedure

  1. Remove the rocker arm cover.
  2. Bring No. 1 cylinder to top dead center on compression: align crank pulley top mark with timing gear case mark.
  3. Loosen the lock nut and adjust clearance between rocker arm and valve guide for intake and exhaust to 0.008 in. (0.2 mm).
  4. Repeat for each cylinder; each set of valves must be adjusted individually.
  5. Replace rocker arm cover and tighten cover nuts to 5 - 8 ft/lbs (0.8 - 2.3 kg/m).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Valve clearance 0.008 in. (0.2 mm)
  • Rocker arm cover nuts 5 - 8 ft/lbs (0.8 - 2.3 kg/m)

Full service-parts list: Northern Lights M773L →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.