Northern Lights M753 / M753W2 — Winterizing or Out-of-Service

Maintenance · Generator set

For the Northern Lights M753 / M753W2, from the Northern Lights operator's manual.

Applies to: Northern Lights M753, Northern Lights M753W2

Procedure

  1. Drain fresh water and seawater cooling systems completely; shut off seacocks before opening drain cocks.
  2. Drain water supply lines and wet exhaust line.
  3. Loosen seawater pump cover and drain pump.
  4. Fill fuel tank or add biocide per manufacturer's instructions.
  5. Seal air cleaner inlet, exhaust opening, crankcase breather pipe, and fuel tank vent with plastic bags and tape.
  6. Store set in dry, protected place; cover if stored outside.
  7. Change crankcase oil and filter.
  8. Loosen alternator belt.
  9. Disconnect and clean battery; remove to warm storage if possible.
  10. Clean outside of unit; paint scratched or chipped surfaces; apply corrosion preventative to exposed metal.

Full service-parts list: Northern Lights M753 →, Northern Lights M753W2 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.