Northern Lights M175C2 — Heat Exchanger Cleaning
Maintenance
For the Northern Lights M175C2, from the Northern Lights operator's manual.
Applies to: Northern Lights M175C2
Procedure
- Drain cooling system.
- Remove cooling water pipes between heat exchanger and water pump inlet.
- Disconnect hose to seawater pump.
- Unscrew bolts holding heat exchanger to expansion tank.
- Remove bolts holding heat exchanger cover.
- Wash core inside and out; clean accessible housing parts.
- Reassemble using new gaskets and sealing rings.
Full service-parts list: Northern Lights M175C2 →
Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.