Home›Repair guides›Northern Lights›Air Cleaner Service

Northern Lights M175C2 — Air Cleaner Service

Maintenance

For the Northern Lights M175C2, from the Northern Lights operator's manual.

Applies to: Northern Lights M175C2

Before you start

  • Do not run engine with air cleaner removed.

Parts for this job

Part numbers from the service-parts list for Northern Lights M175C2. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Inspect air cleaner valve daily.
  2. Replace filter when restriction indicator shows 625 mm (25 in.) H2O.
  3. Loosen hose clamp and attaching strip.
  4. Ensure rubber tube is good and new filter clean and properly installed.
  5. Start engine and check for leaks.

Specs & values

  • Restriction indicator 625 mm (25 in.) H2O

Full service-parts list: Northern Lights M175C2 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.