Northern Lights M150A13 / M80A13 — Starting
Operation · Engine
For the Northern Lights M150A13 / M80A13, from the Northern Lights owner's manual.
Applies to: Northern Lights M150A13
Procedure
- Hold Shutdown Bypass switch in ON position.
- Push Engine Control switch to START.
- Release both switches as soon as engine starts.
- Do not crank starter more than 20 seconds.
- If engine fails to start, wait 2 minutes before retry.
- Run high idle 1 to 2 minutes before adding load.
Full service-parts list: Northern Lights M150A13 →