Northern Lights M1064H / M1066H — Crankcase Vent System

Maintenance

For the Northern Lights M1064H / M1066H, from the Northern Lights operator's manual.

Applies to: Northern Lights M1064H, Northern Lights M1066H, John Deere Powertech Tier II 4045 engine, John Deere Powertech Tier II 6068 engine

Before you start

  • Perform service with engine shut down.

Procedure

  1. Check red filter service indicator button daily; if it pops up, change filter element.
  2. After changing element, unscrew clear plastic cover on button and push indicator down to reset.
  3. Replace cover.
  4. Normally change filter element every 750 hours.
  5. Check hoses and O-rings on crankcase vent system.

Specs & values

  • Filter element normally every 750 hours; chart states change element at 500 hours

Full service-parts list: Northern Lights M1064H →, Northern Lights M1066H →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.