Northern Lights L6125 — Shutdown

Operation · Engine

For the Northern Lights L6125, from the Northern Lights operator's manual.

Applies to: Northern Lights L6125, Northern Lights L6125H engine

Before you start

  • Do not turn battery switch to OFF while engine is running.

Procedure

  1. Run engine three to five minutes in neutral at 1000 RPM for cool down.
  2. Return engine to low idle.
  3. Turn key switch counterclockwise as far as possible to stop engine.
  4. Close seacock and fuel valves.
  5. Put battery switch in OFF position.

Specs & values

  • Cool-down 3 to 5 minutes at 1000 RPM in neutral

Full service-parts list: Northern Lights L6125 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.