Procedure
- Check zincs every 250 hours; more often in warm salt water.
- Drain raw water from heat exchanger.
- Remove zinc holders from back of tank and front and port side of heat exchanger.
- Scrape or steel brush zinc electrode clean.
- Replace zinc if more than 50% eroded.
- Reinstall zinc holders with clean threads and good metal-to-metal contact.
Tools required
- Steel brush Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Replace zinc if more than 50% eroded
Full service-parts list: Northern Lights L1276A2 →