Northern Lights — Generator Set Starting and Operating
Operation
From a Northern Lights owner's manual covering: L439, L668, M40C, M439, M445, M65C, M668, M99C. Check it applies to your exact model before use.
Applies to: Northern Lights M668
Before you start
- Do not crank starter for more than 20 seconds.
Procedure
- Hold Shutdown Bypass switch ON and push Engine Control switch to START.
- Release both switches as soon as engine starts.
- If engine fails to start, be sure starter has stopped before reengaging.
- Check gauges often: oil pressure above 29 PSI, DC voltmeter 13-14 volts.
- Let unit run unloaded three to five minutes warm-up.
- Do not add full electrical load until engine at maximum operating temperature.
Specs & values
- Oil pressure above 29 PSI
- D.C. voltmeter 13 to 14 volts (26-28 volts, 24 volt systems) at 60°F
- Water temperature below 200°F (94°C)
Full service-parts list: Northern Lights M668 →
Source: Northern Lights owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.