Low Voltage Alternator - 4 poles — NDE Bearing Replacement on Single Bearing Machines
For the Low Voltage Alternator - 4 poles.
Procedure
- Remove the air ducts (3)
- Remove the NDE bracket (36)
- Remove the ball bearing (70) using a screw puller
- Heat the inner slipring of a new bearing by induction or in a drying oven at 80 °C (do not use an oil bath) and fit it to the alternator
- Place the preloading wavy washer (79) in the bracket
- Replace the NDE bracket (36)
- Replace the air ducts (3)
Tools required
- Screw puller
Source: manual:5960_en.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.