Home›Repair guides›MTU›Valve clearance - Check and adjustment

MTU 12V 1600 R50 — Valve clearance - Check and adjustment

Adjustments · Valve drive

For the MTU 12V 1600 R50, from the MTU operator's manual.

Applies to: MTU 12V1600R50 engine

Before you start

  • Engine is stopped and starting disabled

Procedure

  1. Engine stopped and starting disabled; coolant temperature max 40 C.
  2. Remove cylinder head cover and flywheel housing cover, A side.
  3. Rotate crankshaft with barring gear until OT-A1 mark and pointer aligned.
  4. Check valve clearance in two crankshaft positions (firing TDC and overlap TDC of A1).
  5. Use feeler gage between valve bridge and rocker arm.
  6. If deviation exceeds 0.1 mm, adjust valve clearance.
  7. Loosen locknut, readjust adjusting screw until feeler gage just passes.
  8. Tighten locknut M10x1 to 43 Nm +4 Nm; install covers.

Tools required

  • Feeler gage Y20010128 Amazon
  • Torque wrench 20-100 Nm F30026582 Amazon
  • Box wrench 14 mm F30028346 Amazon
  • Allen key 5 mm F30002815 Amazon
  • Barring gear F6790714 / F67907 Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Inlet 0.3 +/- 0.05 mm cold
  • Exhaust 0.6 +/- 0.05 mm cold
  • Locknut M10x1 43 Nm +4 Nm

Source: MTU operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.