Home›Repair guides›MTU›Plant - Cleaning

MTU 12V 1600 R50 — Plant - Cleaning

Maintenance

For the MTU 12V 1600 R50, from the MTU operator's manual.

Applies to: MTU 12V1600R50 engine

Before you start

  • Never direct air jet at people.
  • Never direct water jet at people.
  • Do not aim compressed air gun directly at seals or electronic components.

Procedure

  1. Seal all openings in a suitable way.
  2. Remove coarse dirt.
  3. Spray on cleaner sparingly and leave it for 1 to 5 minutes.
  4. Use high-pressure jet to remove loosened dirt.
  5. Dry engine with compressed air.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • High-pressure jet (cleaning jet) pressure must not exceed 50 bar
  • Minimum distance between spray nozzle and plant of 1 m
  • Temperature of cleaning medium must not exceed 80°C

Source: MTU operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More MTU repair guides →