MTU 12V 1600 R50 — Engine coolant - Draining
Maintenance · Coolant circuit
For the MTU 12V 1600 R50, from the MTU operator's manual.
Applies to: MTU 12V1600R50 engine
Before you start
- Coolant is hot and under pressure; risk of injury and scalding
Procedure
- Provide container to drain coolant into; switch off preheater if installed.
- Release pressure at breather valve and remove.
- Draw off precipitated corrosion inhibitor oil from expansion tank.
- Open drain screw and drain coolant at engine coolant pump.
- Open drain screws and drain coolant at crankcase right and left sides.
- Install drain screw with new sealing ring.
- Place breather valve on filler neck and close.
Source: MTU operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.