Procedure

  1. Place trowel on a test plate and check that all adjustment bolts barely contact the lower wear plate.
  2. Set adjustment tool P/N 1817 for clockwise blade rotation (fixture arm in UP position).
  3. Set bolt-to-fixture-arm distance to 7/8 in for pre-June-1982 trowels, 1/2 in for post-June-1982.
  4. Un-screw locking bolts and place the trowel arm into the fixture channel.
  5. Tighten locking bolts with an allen wrench to lock the trowel arm in place.
  6. Loosen the locking nut, then turn the adjusting bolt until it barely touches (.010 in) the fixture bolt.
  7. Tighten the lock nut on the trowel arm lever to lock in place.
  8. Remove the trowel arm from the fixture and repeat for all remaining arms.

Tools required

  • Trowel arm adjustment tool P/N 1817 Amazon
  • Allen wrench Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 7/8 in (pre-1982) or 1/2 in (post-1982) bolt-to-fixture arm distance
  • .010 in bolt contact

Source: MQ Power owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.