Procedure

  1. Clean and examine the upper/lower wear plates and thrust collar; replace damaged parts.
  2. Make sure the bronze trowel arm bushing is not damaged or out of round.
  3. Insert all trowel arms with levers into the spider plate, aligning grease holes.
  4. Lock trowel arms in place with the hex head zerk grease fitting and jam nut.
  5. Reinstall the blades onto the trowel arms and install the stabilizer ring.
  6. Reinstall lower wear plate, thrust collar and upper wear ring onto the spider shaft.
  7. Lubricate all grease points with Lithium 12 based NLGI Grade #2 grease.

Source: MQ Power owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.