Home›Repair guides›MQ Power›Preparation for Long-Term Storage

MQ Power — Preparation for Long-Term Storage

Maintenance · Engine / unit

From a MQ Power owner's manual — check it applies to your exact model before use.

Browse MQ Power generators & specs →

Procedure

  1. Drain the fuel tank completely, or add STA-BIL to the fuel.
  2. Run the engine until the gasoline in the carburetor is completely consumed.
  3. Completely drain the oil from the crankcase and refill with fresh oil.
  4. Remove the spark plug, pour 2–3 cc of SAE 30 oil into the cylinder, and crank slowly to distribute the oil.
  5. Slowly rotate the engine a few times with the starter rope and install a new plug.
  6. Pull out the starter rope slowly and stop at the compression point.
  7. Clean all external parts of the engine and frame with a soft cloth.
  8. Cover the unit and store in a clean, dry place.

Specs & values

  • 2–3 cc SAE 30 oil into cylinder

Source: MQ Power owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.