Home›Repair guides›MQ Power›Generator Start-Up Procedure (Manual)

MQ Power CS-6369 / DCA180SSI — Generator Start-Up Procedure (Manual)

Operation

For the MQ Power CS-6369 / DCA180SSI, from the MQ Power operator's manual.

Applies to: MQ Power DCA180SSI, Isuzu 6HK1X engine

Before you start

  • NEVER manually start the engine with the main, GFCI or auxiliary circuit breakers in the ON (closed) position.

Procedure

  1. Place main, GFCI and aux. circuit breakers in OFF position.
  2. Make sure voltage change-over board is configured for desired output voltage.
  3. Connect load to receptacles or output terminal lugs.
  4. Tighten terminal nuts securely to prevent load wires slipping out.
  5. Close all engine enclosure doors.
  6. Place engine speed switch in LOW (down) position.
  7. Place MPEC control switch in MANUAL position to start engine.
  8. Let engine run 1-2 minutes, then place engine speed switch in HIGH.

Specs & values

  • Oil pressure 290~490 kPa
  • Coolant temperature 75°~95°C
  • Speed approximately 1800 RPM

Full service-parts list: MQ Power DCA180SSI →, Isuzu 6HK1X engine →

Source: MQ Power operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.