Before you start
- Before initial use, disassemble the Quick Disconnect coupler at the end of the flexible shaft. Check the shaft for grease and reassemble the coupler, applying Loctite 242 thread sealant to the male threads.
Procedure
- Pull up on the Quick Disconnect (Q.D.) locking knob and insert the Q.D. coupler into the eccentric end bell assembly.
- Attach the vibrating head to the other end of the flexible shaft.
- Apply a small amount of pipe thread sealant (Red Loctite 271) to the flexible shaft casing coupling threads.
- Screw the head tightly onto the flexible shaft casing and wait one hour before use. Threads are left-handed; turn counterclockwise to tighten.
Specs & values
- Red Loctite 271
Source: MQ Power owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.