Home›Repair guides›MQ Power›Air Cleaner Maintenance

MQ Power — Air Cleaner Maintenance

Maintenance

From a MQ Power manual covering: DCA-300SSK, DCA-300SSK II, DCA300SSK. Check it applies to your exact model before use.

Applies to: MQ Power DCA-300SSK, Komatsu SA6D125E-2 engine

Before you start

  • Use appropriate air pressure to avoid damaging element

Parts for this job

Part numbers from the service-parts lists for MQ Power DCA-300SSK, Komatsu SA6D125E-2 engine. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Loosen wing bolt, remove dust cup
  2. Remove wing nut and take out element
  3. Clean the inside of the body and cover using a damp cloth
  4. Blow dry with compressed air (0.69Mpa maximum) against the side of the element
  5. Blow dry against outside along the pleats, then against inside again
  6. Remove one seal each time the element is cleaned
  7. Replace outer element after cleaning 6 times or after one year

Tools required

  • compressed air equipment Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 0.69 Mpa maximum air pressure

Full service-parts list: MQ Power DCA-300SSK →, Komatsu SA6D125E-2 engine →

Source: MQ Power manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.