Mitsubishi S12A2 — Clean or change the air-cleaner element
Maintenance · Air inlet system
For the Mitsubishi S12A2, from the Mitsubishi owner's manual.
Applies to: Mitsubishi S12A2, Mitsubishi S12A2 engine
Before you start
- Never service the air cleaner when the engine is running.
- Wear a protective face shield, goggles and protective clothing when using pressurized air.
- Do not clean the element by bumping or tapping.
Procedure
- Direct pressurized air inside the element along the length of pleats, maximum 0.69 MPa (7 kgf/cm2) [100 psi].
- Insert a light inside the clean dry element and inspect; discard if rips or tears are found.
- To change: remove the cap from the air cleaner body.
- Remove the wing nut securing the element and take out the used element.
- Install a new element and refit the wing nut and cap.
Tools required
- Pressurized air supply Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Maximum air pressure 0.69 MPa (7 kgf/cm2) [100 psi]
Full service-parts list: Mitsubishi S12A2 →
Source: Mitsubishi owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.