Home›Repair guides›Mitsubishi›Inspecting the battery (electrolyte level and specific gravity)

Mitsubishi — Inspecting the battery (electrolyte level and specific gravity)

Maintenance

From a Mitsubishi owner's manual — check it applies to your exact model before use.

Browse Mitsubishi generators & specs →

Before you start

  • Do not use open flames or other fire hazards near the battery.
  • Battery electrolyte contains dilute sulfuric acid; wear protective goggles and rubber gloves.

Procedure

  1. Check the electrolyte level; correct level is between LOWER LEVEL and UPPER LEVEL lines.
  2. For batteries without level lines, keep the fluid about 10 to 15 mm above the top of the plates.
  3. If the fluid level is low, remove the caps and add distilled water to the proper level.
  4. Measure the specific gravity of the electrolyte at 20°C [68°F].
  5. If specific gravity is lower than 1.22, charge the battery.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Specific gravity 1.26 to 1.28 fully charged; 1.22 to 1.26 charged; less than 1.22 discharged

Source: Mitsubishi owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.