Mitsubishi GS16R-PTK — Break-In Operation
Operation · Engine
For the Mitsubishi GS16R-PTK, from the Mitsubishi service manual.
Applies to: Mitsubishi GS16R-PTK, Mitsubishi GS16R-PTK engine
Before you start
- Be prepared to activate the emergency stop for an unforeseeable trouble.
Procedure
- Stop the gas supply and crank the engine approx. 10 seconds with starter; repeat 2 or 3 times with one minute intervals.
- Start the engine in the normal procedure and confirm low idle speed.
- Make sure oil pressure increases immediately and coolant circulates.
- Confirm no oil, coolant or fuel gas leaks, and no abnormal noise or vibration.
- Increase load progressively per the break-in table.
Specs & values
- Idling no-load 5 min
- 1000 min-1 no-load 5 min
- 1200 min-1 no-load 10 min
- 1500 min-1 no-load 10 min
- Rated speed 25% 10 min, 50% 10 min, 75% 30 min, 100% 20 min
Source: Mitsubishi service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.