Home›Repair guides›Mitsubishi›Break-In Operation

Mitsubishi GS16R-PTK — Break-In Operation

Operation · Engine

For the Mitsubishi GS16R-PTK, from the Mitsubishi service manual.

Applies to: Mitsubishi GS16R-PTK, Mitsubishi GS16R-PTK engine

Before you start

  • Be prepared to activate the emergency stop for an unforeseeable trouble.

Procedure

  1. Stop the gas supply and crank the engine approx. 10 seconds with starter; repeat 2 or 3 times with one minute intervals.
  2. Start the engine in the normal procedure and confirm low idle speed.
  3. Make sure oil pressure increases immediately and coolant circulates.
  4. Confirm no oil, coolant or fuel gas leaks, and no abnormal noise or vibration.
  5. Increase load progressively per the break-in table.

Specs & values

  • Idling no-load 5 min
  • 1000 min-1 no-load 5 min
  • 1200 min-1 no-load 10 min
  • 1500 min-1 no-load 10 min
  • Rated speed 25% 10 min, 50% 10 min, 75% 30 min, 100% 20 min

Source: Mitsubishi service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Mitsubishi repair guides →