Home›Repair guides›Mitsubishi›Gauze Filter - Clean

Mitsubishi — Gauze Filter - Clean

Maintenance · Fuel feed pump inlet

From a Mitsubishi operator's manual — check it applies to your exact model before use.

Browse Mitsubishi generators & specs →

Procedure

  1. Remove the eye bolt at the inlet port of the fuel feed pump.
  2. Remove the gauze filter fitted inside the eye bolt using a screw driver.
  3. Soak the gauze filter in fuel and clean it with a brush.
  4. Reinstall the gauze filter into the eye bolt.
  5. Install the eye bolt to the fuel feed pump.
  6. Bleed the air from the fuel filter.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Mitsubishi operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.