Mitsubishi — 3. Remove the wire and press the plunger. If the
A Mitsubishi service procedure — check it applies to your exact model before use.
Browse Mitsubishi generators & specs →
Procedure
- 4. After air bleeding, set the lash adjuster on the
- special tool (Leak down tester 800400).
- 5. After the plunger has gone down somewhat
- (0.2-0.5 mm), the measured time is out of the
- specification.
- Standard value:
- 4-20 seconds/1 mm (Diesel fuel at 15-20℃)
Tools required
- special tool (Leak down tester 800400).
Source: manual:Mitsubishi-2.0L-2.4L-Service-Manual-106992-Revision-D.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.