HomeRepair guides3. Remove the wire and press the plunger. If the

Mitsubishi — 3. Remove the wire and press the plunger. If the

A Mitsubishi service procedure — check it applies to your exact model before use.

Browse Mitsubishi generators & specs →

Procedure

  1. 4. After air bleeding, set the lash adjuster on the
  2. special tool (Leak down tester 800400).
  3. 5. After the plunger has gone down somewhat
  4. (0.2-0.5 mm), the measured time is out of the
  5. specification.
  6. Standard value:
  7. 4-20 seconds/1 mm (Diesel fuel at 15-20℃)

Tools required

  • special tool (Leak down tester 800400).

Source: manual:Mitsubishi-2.0L-2.4L-Service-Manual-106992-Revision-D.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.