Mitsubishi — Service Procedure
A Mitsubishi service procedure — check it applies to your exact model before use.
Browse Mitsubishi generators & specs →
Before you start
- Note: Leave the wire installed in the auto-
Procedure
- 4. Unclamp the auto-tensioner from the vise.
- 800424
- 5. Install the auto-tensioner onto the front case
- and tighten to the specified torque.
- Note: Leave the wire installed in the auto-
- tensioner. Tightening torque: 24± 3 N·m
- >>H<< TIMING BELT INSTALLATION
- 1. Align the timing mark on the camshaft sprocket
- with the timing mark on the rocker cover.
- 2. Align the timing mark on the crankshaft sprocket
- with the timing mark on the front case.
- 3. Align the timing mark on oil pump sprocket with
- its mating mark.
- 4. Remove the plug on the cylinder block and
- insert a Phillips head screwdriver (shank diameter
- 8 mm) through the hole.
- If it can be inserted as deep as 60 mm or more,
- the timing marks are correctly aligned.
- If the inserted depth is only 20 to 25 mm, turn the
- oil pump sprocket one turn and realign the timing
Specs & torque values
- 3 N·m
Source: manual:Mitsubishi-2.0L-2.4L-Service-Manual-106992-Revision-D.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.