Before you start

  • Slave receptacle is electrically live at all times and is unfused; 24 VDC even when disconnect switch is OFF.

Procedure

  1. Connect one end of NATO slave cable to fully charged 24 Vdc system.
  2. Connect other end to discharged generator set NATO SLAVE RECEPTACLE.
  3. On EMCP, set ENGINE CONTROL switch to MANUAL START to start generator.
  4. Remove NATO slave cable after generator set starts.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Military MEP operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.