Before you start

  • Cooling system operates at high temperature and pressure.
  • Do not operate generator set while servicing radiator.

Procedure

  1. Remove radiator cap.
  2. Check that radiator drain valve is closed.
  3. Fill radiator with proper coolant to 2 inches below fill opening.
  4. Remove overflow bottle cap and fill bottle to COLD level.
  5. Install overflow bottle and radiator caps.
  6. After 30 minutes of operation check coolant level and add as required.

Specs & values

  • Fill radiator to a level 2 inches below fill opening.

Full service-parts list: Military MEP MEP-804A →

Source: Military MEP service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.