Home›Repair guides›Military MEP›NATO Slave Receptacle Removal

Military MEP MEP-804A — NATO Slave Receptacle Removal

Maintenance

For the Military MEP MEP-804A, from the Military MEP service manual.

Applies to: Military MEP MEP-804A

Before you start

  • Slave receptacle is electrically live at all times and is unfused; disconnect batteries first.

Procedure

  1. Shut down generator set.
  2. Open battery access door and disconnect negative battery cable.
  3. Open left side engine access door; tag and disconnect battery and slave receptacle cables.
  4. Remove bolts, nuts, and NATO slave receptacle from housing.
  5. Remove nut, bolt, and cover from generator set.

Full service-parts list: Military MEP MEP-804A →

Source: Military MEP service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Military MEP repair guides →