Military MEP MEP-804A — Battery Testing (Specific Gravity)

Maintenance · Batteries

For the Military MEP MEP-804A, from the Military MEP service manual.

Applies to: Military MEP MEP-804A

Before you start

  • Battery acid can cause burns to unprotected skin.
  • Batteries give off a flammable gas.

Procedure

  1. Shut down generator set.
  2. Open battery access door and disconnect negative battery cable.
  3. Remove battery vent caps.
  4. Test specific gravity of electrolyte in each cell with a hydrometer.
  5. Recharge or replace batteries as necessary.
  6. Install vent caps, connect negative cable, close access door.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 1.280 specific gravity = 100 percent charge at 80°F (27°C).

Full service-parts list: Military MEP MEP-804A →

Source: Military MEP service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.