Military MEP MEP-804A — Battery Removal
Maintenance · Batteries
For the Military MEP MEP-804A, from the Military MEP service manual.
Applies to: Military MEP MEP-804A
Before you start
- Disconnect the negative lead to the grounding stud first.
- Each battery weighs more than 70 pounds (32 kg) and requires a two-person lift.
Procedure
- Shut down generator set.
- Open battery compartment access door.
- Disconnect negative battery cable terminal lug.
- Disconnect interconnect battery cable terminals and remove cable.
- Disconnect positive battery cable terminal lug.
- Remove nuts, washers, lock washers, hook bolts, and battery hold-down.
- Remove batteries.
Full service-parts list: Military MEP MEP-804A →
Source: Military MEP service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.