Home›Repair guides›Military MEP›Battery Removal

Military MEP MEP-804A — Battery Removal

Maintenance · Batteries

For the Military MEP MEP-804A, from the Military MEP service manual.

Applies to: Military MEP MEP-804A

Before you start

  • Disconnect the negative lead to the grounding stud first.
  • Each battery weighs more than 70 pounds (32 kg) and requires a two-person lift.

Procedure

  1. Shut down generator set.
  2. Open battery compartment access door.
  3. Disconnect negative battery cable terminal lug.
  4. Disconnect interconnect battery cable terminals and remove cable.
  5. Disconnect positive battery cable terminal lug.
  6. Remove nuts, washers, lock washers, hook bolts, and battery hold-down.
  7. Remove batteries.

Full service-parts list: Military MEP MEP-804A →

Source: Military MEP service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.