Before you start
- Reconnect cables in reverse order of removal.
- Never start the generator set unless it is properly grounded.
Procedure
- Position serviced and fully charged batteries in generator set.
- Apply general purpose grease to battery posts and cable terminal lugs.
- Install hook bolts and battery hold-down with new lock washers, washers, and nuts.
- Connect positive cable terminal lug.
- Position interconnect battery cable connect terminals.
- Connect negative battery cable terminal lug and close access door.
Full service-parts list: Military MEP MEP-804A →
Source: Military MEP service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.