Home›Repair guides›Military MEP›Batteries Inspection and Service

Military MEP MEP-804A — Batteries Inspection and Service

Maintenance

For the Military MEP MEP-804A, from the Military MEP operator's manual.

Applies to: Military MEP MEP-804A, Isuzu C-240 engine

Before you start

  • Battery acid can cause burns; wear goggles and chemical gloves

Procedure

  1. Shut down generator set
  2. Open battery access door
  3. Inspect case, corrosion, connections, battery caps
  4. Remove battery caps
  5. Add distilled water to each cell as required
  6. Replace battery caps
  7. Close battery access door

Tools required

  • Generator Mechanical Tool Kit Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Electrolyte level at bottom of each cap cylinder

Full service-parts list: Military MEP MEP-804A →, Isuzu C-240 engine →

Source: Military MEP operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.