Home›Repair guides›Military MEP›Installation of Ground Rod

Military MEP — Installation of Ground Rod

Installation · Grounding system

From a Military MEP operator's manual — check it applies to your exact model before use.

Browse Military MEP generators & specs →

Before you start

  • Remove all metal jewelry when working on generator set.
  • Never attempt to start generator set unless properly grounded.

Procedure

  1. Remove three ground rods from storage inside left front housing door.
  2. Remove ground cable, clamp, driving stud, and three couplers.
  3. Open output load terminal board TB2 door and remove terminal nut wrench.
  4. Route ground cable through OUTPUT CABLES boot into housing.
  5. Insert ground cable through slot on ground terminal on skid frame and tighten.
  6. Connect coupler to ground rod and screw driving stud into coupler.
  7. Drive ground rod until coupler is just above surface; add sections.
  8. Drive rod 8 feet or deeper; secure cable with clamp.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Drive ground rod 8 feet or deeper

Source: Military MEP operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.