Home›Repair guides›Mecc Alte›Check of residual voltage

Mecc Alte — Check of residual voltage

Testing & diagnosis · electronic regulator

From a Mecc Alte owner's manual — check it applies to your exact model before use.

Before you start

  • Strictly observe polarity (+ to +, - to -)

Procedure

  1. With the generator stopped, remove the terminal box lid
  2. Connect two wires to a 12 Vdc battery with a 30 Ω in-series resistor
  3. Using Mecc Alte diagrams locate the + and - terminals of the electronic regulator
  4. Start the generator
  5. Momentarily apply the two wires to the terminals respecting polarity
  6. Check with a voltmeter that rated voltage is produced

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 12 Vdc battery with 30 Ω series resistor

Source: Mecc Alte owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Mecc Alte repair guides →