Home›Repair guides›Magnum›Raising the Mast

Magnum MLT4200IF4 — Raising the Mast

Operation

For the Magnum MLT4200IF4, from the Magnum operator's manual.

Applies to: Magnum MLT4200IF4, Isuzu 4LE2TAGV-03 engine

Before you start

  • Never raise or lower the mast while the unit is operating
  • Stop immediately if the winch cable develops slack or a mast section sticks

Procedure

  1. Set up and level the unit with outriggers extended
  2. Remove the mast cradle locking pin
  3. Check mast cables and electrical cord for wear or damage
  4. Clear the area around the unit before raising the mast
  5. Remove the safety pin from the mast lock bar and raise the mast with the lower winch until it locks; reinsert the safety pin
  6. Telescope the mast to desired height with the upper winch, watching the electrical cord
  7. Rotate the mast to the desired direction and tighten the rotation knob

Full service-parts list: Magnum MLT4200IF4 →, Isuzu 4LE2TAGV-03 engine →

Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.