Lombardini — Storage preparation (temporary protection 1/6 months)
Maintenance · Engine storage
From a Lombardini service manual covering: 25LD330-2, 25LD425-2, KD 425-2. Check it applies to your exact model before use.
Procedure
- Let engine run at idling speed no-load for 15 minutes.
- Fill crankcase with protection oil MIL-1-644-P9 and run at 3/4 speed for 5/10 minutes.
- When warm, empty oil pan and fill with standard new oil.
- Remove fuel tube and empty tank.
- Remove fuel filter, replace cartridge if dirty and refit.
- Clean cylinder fins, heads and fan.
- Seal all openings with tape.
- Remove injectors, pour spoonful SAE 30 oil into cylinders, rotate manually, refit injectors.
Specs & values
- Protection oil MIL-1-644-P9
Source: Lombardini service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.