Lincoln Electric — Input and Grounding Connections

Installation · Input reconnect panel

From a Lincoln Electric operator's manual — check it applies to your exact model before use.

Before you start

  • Turn the input power OFF at the disconnect switch or fuse box before working on this equipment.
  • Failure to follow these instructions can cause immediate failure of components within the welder.

Procedure

  1. Connect the terminal marked (ground) below the reconnect panel to an earth ground.
  2. Connect the input leads to terminals marked L1 (U) and L2 (V) on the reconnect panel. Use a single phase line or one phase of a two or three phase line.
  3. On multiple input voltage welders, be sure the reconnect panel is connected for the voltage being supplied to the welder.
  4. Reconnect the jumper strap to the terminal stud corresponding to the input voltage level used and make sure all connections are tight.

Specs & values

  • Input wire size per Section A-2
  • Export model: LOW is 220-230V FridayParts $63.99, MID is 380-400V and HIGH is 415V

Source: Lincoln Electric operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.